-12-
Cell Voltage Monitor & Logger CellLog 8S
MAIN MENU
Log Files
System...
Calibration
LOG FILE
⊙Logs OFF
○LogFile1
FILE CREATE
File Name:
LogFile1
LogFile1
File Select
File Transmit
File Empty
File Delete
.
LOG FILE [01230]
⊙Logs OFF
○LogFile1
LogFile1
File Transfer..
00100/01230
Parameter Setup
Press < > for 3 seconds, and enter to the MAIN MENU, Monitor status.
Log File Management: Select【Log Files】, press < > and the screen shows:
The first item is【Logs OFF】,if it is chosen, LOG function is close.
Press <▲> for 3 seconds to create new Log files.
Log file name input method:
<▲> to select characters, hold it to trigger continuously; <▼> to
delete the current character; < > to confirm the selected character;
press < > for 2 times to confirm the amendment and return;
press< > for 3 seconds to cancel and return.
The operation to the existing files:
<▲> or <▼> to select items, press < > to have a select order, press
< > for more than 3 seconds to return.
【File Select】The selected file is the current log file
【File Transmit】Transmit the selected log file to the USB port, it can
be received by ―LogView‖(See details in P17)
【File Empty】Empty all selected log files. Press< >, the screen
shows ‖Are you sure you want to empty?‖, and press < > to confirm,
and any other press to cancel.
【File Delete】Delete the selected file. Press< >, the screen shows
―Are you sure you want to empty?‖, and press < > to confirm, and
any other press to cancel.
Logging number the
file contains